Basic Info.
Application
Construction, Underground, Industrial, Power Station
Voltage
Low and Medium Voltage Cable
Sheath Material
PE or PVC
Material Shape
Round Wire
Wire Core Material
Copper
Model
Nyy,Nayy,N2xy,Nhxmh
Standard
ASTM, AS/NZS, BS, CSA, DIN, IEC...
Transport Package
Packed in Reels
Specification
as per popular standards or clients′s requirement
Product Description
Nayy Cable Nyy XLPE Insulated STA Armored PVC Sheathed Power cable N2XY cableVoltage: 0.6/1KV,1.8/3KV, 3.6/6KV ,35kV and below.
Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.Product Named:
1. The meaning of cable model in letter and number:
T....................................Copper conductor
L....................................Aluminum conductor
YJ..................................XLPE
V....................................PVC
Y....................................PE
Armor code:
2....................................Double steel tape armor
3....................................Thin steel wire armor
4....................................Thick steel wire armor
6....................................(Double)non-magnetic mental tape armor
7....................................Non-magnetic wire armor
Oversheath code:
2....................................PVC oversheath
3....................................PE oversheath
4....................................Elastomer oversheath
Using Festures of Power Cable:
1.Rated Voltage 0.6/1kV PVC Insulation Power Cable :
The long-term working temperature of cable conductor should be not more than 70°C.
While short-circuit the highest working temperature of cable conductor should be not more than 160°C(5 seconds maximum duration);
The minimum bending radius for laying cable(D is diameter):single core unarmoured cable shoule be 20D,multi-core unarmoured cable shoule be 15D,single core armoured cable shoule be 15D,multi-core armoured cable should be 12D;
The environment temperature for laying cable should be not less than 0°C.
2. Rated Voltage 0.6/1kV XLPE Insulation Power Cable / Rated Voltage 3.6/6~26/35kV XLPE Insulation Power Cable :
The long-term working temperature of cable conductor should be not more than 90°C.
While short-circuit the highest working temperature of cable conductor should be not more than 250°C(5 seconds maximum duration);
3. Rated Voltage 0.6/1kV and Freqency Inverter Control System Power Cable :
Designed with fully symmetric space structure,cable has excellent electromagnetic compatibility;
Low and uniform positive sequence and zero-sequence impedances have greatly improved power quality compared with ordinary four-core cable;
The environment temperature for laying cable;PVC and XLPE insulation is 0°C;
The maximum working temperature of cable;PVC insulation is 70°C,XLPE insulation is 90°C;
Low-smoke halogen-free flame retardant cable:PH value of burning gas ≥4.3,conductivity≤10us/mm,minimum light transmittance shall not be less than 60% while product burning;
The minimum bending radius for laying cable is 12D(D is diameter).
4. Copper Clad Aluminum Power Cable
Maximum temperature of cable of cable conductors during normal operation and short-circuit (5 seconds maximum duration): PVC insulation is 70oC, the highest temperature should be not more than 160oC while short circuit; XLPE insulation is 90oC,the highest temperature should be not more than 250oC while short circuit;
The minimum bending radius for laying cable (D is diameter):single core unarmoured is 20D,three-core unarmoured is 15D, single core armoured is 15D,three-core armoured is 12D;
The environmental remperature for laying cable should not less than 0oC
Product description
Rated Voltage 0.6/1kV XLPE Insulation Power Cable
Type | Description | Application |
Cu | Al |
YJV | YJLV | Copper-core(aluminum core)XLPE insulation and PVC sheath power cable | For laying indoor,in tunnels and in ducts,unable to bear external mechanical forces |
YJY | YJLY | Copper-core(aluminum core)XLPE insulation and PE sheath power cable |
YJV22 | YJLV22 | Copper-core(aluminum core)XLPE insulation steel tape armoured PVC sheath power cable | For laying indoor,in tunnels and in ducts,can able to bear external mechanical forces |
YJV23 | YJLV23 | Copper-core(aluminum core)XLPE insulation steel tape armoured PE sheath power cable |
YJV32 | YJLV32 | Copper-core(aluminum core)XLPE insulation steel wire armoured PVC sheath power cable | For laying in water or ground along route with large difference of level,can able to bear external mechanical forces |
YJV33 | YJLV33 | Copper-core(aluminum core)XLPE insulation steel wire armoured PE sheath power cable |
YJV42 | YJLV42 | Copper-core(aluminum core)XLPE insulation thick wire armoured PVC sheath power cable |
YJV43 | YJLV43 | Copper-core(aluminum core)XLPE insulation thick wire armoured PE sheath power cable |
Notes:1.Ratproof,termite-proof,moisture-proof and other special requiremments cables are available.
2.The single core armoured cable are used for DC system only.As for AC system,non-megnetical materials shoule be used,its corresponding code is 62,63,72,73;
3.It is not recommended AL-core fire retardent cable.When there is a fire,flame temperatures may reach 700°C above due to the meilting point of aluminium is only 660°C,the conductor may be fused;
4.Flame retaradant/fire resistant power cable are available:Representation method of flame retardant grade is the "Z" followed by"A","B","C",such as the "ZA","ZB","ZC".When "ZR" expressed,generally considered to be "C" class of flame retardant.Flame retardant level representation is "ZN" middle "A","B","C",such as the "ZA","ZB","ZC".While using "NH" expressed,it generally considered to be "ZCN".For example;
Notes:1.Flexible power cable is available.Plus "R" after sheath material types.For example,"VVR" refers to cooper core PVC insulation PVC sheath flexible power cable;
2.Hear-resistant 90°C and 105°C power cable are available,Plus "-90" "-105" after the type.For example,VV-105 refers to copper core heat-resistant 105°C PVC insulation and sheath power cable,and the highest temperature of cable conductor is 105°C.
3.Ratproof,termite-proof,moisture-proof and other special requiremments cables are available.
4.The single core armoured cable are used for DC system only.As for AC system,non-megnetical materials shoule be used,its corresponding code is 62,63,72,73;
5.It is not recommended AL-core fire retardent cable.When there is a fire,flame temperatures may reach 700°C above due to the meilting point of aluminium is only 660°C,the conductor may be fused;
6.Flame retaradant/fire resistant power cable are available:Representation method of flame retardant grade is the "Z" followed by"A","B","C",such as the "ZA","ZB","ZC".When "ZR" expressed,generally considered to be "C" class of flame retardant.Flame retardant level representation is "ZN" middle "A","B","C",such as the "ZA","ZB","ZC".While using "NH" expressed,it generally considered to be "ZCN".For example;
Rated Voltage 0.6/1kV PVC Insulation Power Cable :
Type | Description | Application |
Cu | Al |
VV | VLV | Copper-core(aluminum core)PVC insulation and PVC sheath power cable | For laying indoor,in tunnels and in ducts,unable to bear external mechanical forces |
VY | VLY | Copper-core(aluminum core)PVC insulation and PE sheath power cable |
VV22 | VLV22 | Copper-core(aluminum core)PVC insulation steel tape armoured PVC sheath power cable | For laying indoor,in tunnels and in ducts,can able to bear external mechanical forces |
VY23 | VLY23 | Copper-core(aluminum core)PVC insulation steel tape armoured PE sheath power cable |
VV32 | VLV32 | Copper-core(aluminum core)PVC insulation steel wire armoured PVC sheath power cable | For laying in water or ground along route with large difference of level,can able to bear external mechanical forces |
VY33 | VLY33 | Copper-core(aluminum core)PVC insulation steel wire armoured PE sheath power cable |
VV42 | VLV42 | Copper-core(aluminum core)PVC insulation thick wire armoured PVC sheath power cable |
VY43 | VLY43 | Copper-core(aluminum core)PVC insulation thick wire armoured PE sheath power cable |
Patameter fof sinle core power cable
Size | Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 20ºC(Ω/km) |
1x50mm 2 | 10.5 | 0.12 | 2.1 | 38.2 | 0.387 |
1x70mm 2 | 10.5 | 0.12 | 2.2 | 40.1 | 0.268 |
1x95mm 2 | 10.5 | 0.12 | 2.2 | 41.7 | 0.193 |
1x120mm 2 | 10.5 | 0.12 | 2.3 | 43.3 | 0.153 |
1x150mm 2 | 10.5 | 0.12 | 2.3 | 44.9 | 0.124 |
1x185mm 2 | 10.5 | 0.12 | 2.4 | 46.7 | 0.0991 |
1x240mm 2 | 10.5 | 0.12 | 2.5 | 49.3 | 0.0754 |
1x300mm 2 | 10.5 | 0.12 | 2.5 | 51.3 | 0.0601 |
1x400mm 2 | 10.5 | 0.12 | 2.6 | 54.7 | 0.0470 |
1x500mm 2 | 10.5 | 0.12 | 2.7 | 58.2 | 0.0366 |
1x630mm 2 | 10.5 | 0.12 | 2.8 | 62.0 | 0.0283 |
1x800mm 2 | 10.5 | 0.12 | 3.0 | 66.2 | 0.0221 |
Patameter fof 3 core Power cable
Size | Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of steel tape(mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 20ºC(Ω/km) |
3x25mm 2 | 3.4 | 0.10 | 0.5 | 2.3 | 45.7 | 0.727 |
3x35mm 2 | 3.4 | 0.10 | 0.5 | 2.4 | 48.1 | 0.524 |
3x50mm 2 | 3.4 | 010 | 0.5 | 2.5 | 50.9 | 0.387 |
3x70mm 2 | 3.4 | 0.10 | 0.5 | 2.6 | 54.8 | 0.268 |
3x95mm 2 | 3.4 | 0.10 | 0.5 | 2.7 | 58.8 | 0.193 |
3x120mm 2 | 3.4 | 0.10 | 0.5 | 2.9 | 62.4 | 0.153 |
3x150mm 2 | 3.4 | 0.10 | 0.5 | 3.0 | 66.2 | 0.124 |
3x185mm 2 | 3.4 | 0.10 | 0.5 | 3.1 | 70.1 | 0.0991 |
3x240mm 2 | 3.4 | 0.10 | 0.5 | 3.3 | 75.9 | 0.0754 |
3x300mm 2 | 3.4 | 0.10 | 0.5 | 3.4 | 80.7 | 0.0601 |
3x400mm 2 | 3.4 | 0.10 | 0.8 | 3.7 | 89.8 | 0.0470 |
Patameter fof 4 core Power cable
Cable size | Conductor type | Nominal thickness of XLPE insulation(mm) | Nominal thickness of PVC or PE sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 20ºC(Ω/km) |
4x1.5mm 2 | RE or RM | 0.7 | 1.8 | 10.5 | 18.1 |
4x2.5mm 2 | RE or RM | 0.7 | 1.8 | 11.5 | 12.1 |
4x4mm 2 | RE or RM | 0.7 | 1.8 | 12.6 | 7.41 |
4x6mm 2 | RE or RM | 0.7 | 1.8 | 13.8 | 4.61 |
4x10mm 2 | RM | 0.7 | 1.8 | 16.9 | 3.08 |
4x16mm 2 | RM | 0.7 | 1.8 | 19.5 | 1.91 |
4x25mm 2 | SM | 0.9 | 1.8 | 21.3 | 1.20 |
4x35mm 2 | SM | 0.9 | 1.8 | 23.4 | 0.868 |
4x50mm 2 | SM | 1.0 | 1.9 | 26.8 | 0.641 |
4x70mm 2 | SM | 1.1 | 2.0 | 30.6 | 0.443 |
4x95mm 2 | SM | 1.1 | 2.1 | 34.9 | 0.320 |
4x120mm 2 | SM | 1.2 | 2.3 | 38.4 | 0.253 |
4x150mm 2 | SM | 1.4 | 2.4 | 42.5 | 0.206 |
4x185mm 2 | SM | 1.6 | 2.6 | 47.4 | 0.164 |
4x240mm 2 | SM | 1.7 | 2.8 | 53.4 | 0.125 |
4x300mm 2 | SM | 1.8 | 3.0 | 59.0 | 0.100 |
Address:
Building 6, Qinhe Road, Zhongyuan District, Zhengzhou City, Henan Province, Zhengzhou, Henan, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Zhengzhou JINYUAN Wire and Cable Co., Ltd, as a professional cable manufacturer. We have get ISO9001 and CE certificates. Our Professional and complete cable solutions make JYTOP Cables become to the partner of choice for international companies around the world,
PRODUCTS & STANDARDS & International Market:
1). Bare Conductor:
All Aluminum Conductor (AAC),
All Aluminum Alloy Conductor (AAAC),
Aluminum Conductor Steel Reinforced (ACSR),
Aluminum Alloy Conductor Steel Reinforced (AACSR),
Aluminum Conductor Aluminum Coated Steel Reinforced (ACSR/AW),
Aluminum Conductor Aluminum Alloy Reinforced (ACAR),
Aluminum Conductor Steel Supported (ACSS),
Aluminum Conductor Aluminum Coated Steel Reinforced (ACSR/AW)
All Copper Conductors(ACC),
Aluminum Coated Steel Wire(ACS),
Copper Coated Steel Wire(CCS),
Copper Coated Aluminum(CCA),
Galvanized Steel Wire(GSW),
Enameled Wire - Enameled round Aluminum Wire & Enameled round copper Wire
2). Overhead Cable:
Aerial Bundled Cable (ABC).
XLPE Cable,
Flexible Cable,
Single Core Cable,
2 Core Cable,
3 Core Cable,
4 Core Cable.
3). Building wire and cable:
THHN /THWN Cable
TW/THW Cable
PVC Insulated Wire,
XLPE Insulated cable.
4. Power Cable:
Armored /Non-armored Power cable
AWA Cable
SWA Cable
Standards: IEC, ASTM, AS/NZ, SANS, BS, DIN, NF, JISC, etc.
We can meet customers′ special requirements, and provided OEM service.
Mainly Oversea Marketing: Southeast Asia, The Middle East, Africa, South America, so on.
We will be recognized as a professional Manufacturer in cable industry, through continuous improvement of our product quality, after sales service. We can give you the reliable solution for cable wires.
Company website: jytopcable.en.made-in-china.com