Basic Info.
Model NO.
ABC 3*50mm+1*54.6mm,
Conductor Material
Aluminum
Material Shape
Round Wire
Range of Application
Overhead
Certification
ISO9001, CE, RoHS
Standard
ASTM, BS, DIN, IEC
Transport Package
Packed in Coils or Reels
Specification
3*16mm to 3*70mm
Product Description
MV ABC NFC 1*50+1*54.6mm Aerial bundled service drop cable
Service Drop aerial boundle ABC cable
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM ANSI/ICEA S-76-474 NF C 33-209 standard.
LV ABC cable(Aerial Bundle cable) with AAAC conductor
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, Duplex, Triplex, Quadruplex.
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
TYPE ONE service drop wire ABC cable
ABC CABLE -aerial bundle cable :are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
Applications
To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction
Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request.
Standards
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Data sheet
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Rating(Amps) |
Name | 1000 ft(lbs) |
| Size | Strand | Insulation | Size | *Strand | Breaking | XLP | POLY | XLP | POLY |
| AWG | thickness | AWG | strength |
| | (mls) | | (lbs) |
AAC |
Pekingese | 6 | solid | 45 | 6 | 7/w | 563 | 63.5 | 61.7 | 70 | 70 |
Collie | 6 | 7/w | 45 | 6 | 7/w | 563 | 66.8 | 63.1 | 70 | 70 |
Dachshund | 4 | solid | 45 | 4 | 7/w | 881 | 95.5 | 93.4 | 90 | 90 |
Spaniel | 4 | 7/w | 45 | 4 | 7/w | 881 | 101 | 95.4 | 90 | 90 |
Doberman | 2 | 7/w | 45 | 2 | 7/w | 1,350 | 153 | 145.7 | 120 | 120 |
Malemute | 1/0 | 19/w | 60 | 1/0 | 7/w | 1,990 | 243 | 234.2 | 160 | 160 |
ACSR NEUTRAL-MESSENGER |
Setter | 6 | solid | 45 | 6 | '6/1 | 1.19 | 75 | 73.2 | 70 | 70 |
Shepherd | 6 | 7/w | 45 | 6 | '6/2 | 1.19 | 78.3 | 74.6 | 70 | 70 |
Eskimo | 4 | solid | 45 | 4 | '6/3 | 1.86 | 114 | 111.6 | 90 | 90 |
Terrier | 4 | 7/w | 45 | 4 | '6/4 | 1.86 | 119 | 113.6 | 90 | 90 |
Chow | 2 | 7/w | 45 | 2 | '6/5 | 2.85 | 182 | 174.7 | 120 | 120 |
Bull | 1/0 | 19/w | 60 | 1/0 | '6/6 | 4.38 | 289 | 280.3 | 160 | 160 |
6201 ALLOY NEUTRAL-MESSENGER |
Chihuahua | 6 | solid | 45 | 6 | 7/w | 1,110 | 67.6 | 65.8 | 70 | 70 |
Vizsla | 6 | 7/w | 45 | 6 | 7/w | 1,110 | 70.9 | 67.2 | 70 | 70 |
Harrier | 4 | solid | 45 | 4 | 7/w | 1,760 | 102 | 99.9 | 90 | 90 |
Whippet | 4 | 7/w | 45 | 4 | 7/w | 1,760 | 107 | 101.9 | 90 | 90 |
Schnauzer | 2 | 7/w | 45 | 2 | 7/w | 2,800 | 163 | 156.2 | 120 | 120 |
Heeler | 1/0 | 19/w | 60 | 1/0 | 7/w | 4,460 | 259 | 250.8 | 160 | 160 |
Triplex Service Drop-Aluminum Conductor
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Ampacity (Amps) |
Name | 1000 ft(lbs) |
| Size | Stranding | Insulation | Size | Stranding | Breaking | XLP | POLY | XLP | POLY |
| AWG | thickness | AWG | strength |
| | (mls) | | (lbs) |
6201 ALLOY NEUTRAL-MESSENGER |
Minex | 6 | solid | 45 | 6 | 7 | 1,110 | 106.6 | 102.9 | 85 | 70 |
Hippa | 6 | 7/w | 45 | 6 | 7 | 1,110 | 113.2 | 105.7 | 85 | 70 |
Prawn | 4 | solid | 45 | 4 | 7 | 1,760 | 158.4 | 154.1 | 115 | 90 |
Barnacles | 4 | 7/w | 45 | 4 | 7 | 1,760 | 168.3 | 158.2 | 115 | 90 |
Shrimp | 2 | 7/w | 45 | 2 | 7 | 2,800 | 253.7 | 239.7 | 150 | 120 |
Gammarus | 1/0 | 7/w | 60 | 1/0 | 7 | 4,460 | 411.7 | 386 | 205 | 160 |
Leda | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 402.7 | 386 | 205 | 160 |
Dungenese | 2/0 | 7/w | 60 | 2/0 | 7 | 5,390 | 506.8 | 476.3 | 235 | 185 |
Cyclops | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 495.3 | 476.3 | 235 | 185 |
Flustra | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 611.4 | 589.1 | 275 | 215 |
Lepas | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 757.1 | 730.5 | 315 | 245 |
6201 ALLOY REDUCED NEUTRAL-MESSENGER |
Artemia | 4 | solid | 45 | 6 | 7 | 1,110 | 141.4 | 137.1 | 115 | 90 |
Crab | 4 | 7/w | 45 | 6 | 7 | 1,110 | 151.3 | 141.2 | 115 | 90 |
Solaster | 2 | 7/w | 45 | 4 | 7 | 1,760 | 226.6 | 212.6 | 150 | 120 |
Sandcrab | 1/0 | 7/w | 60 | 2 | 7 | 2,800 | 368.8 | 343.1 | 205 | 160 |
Echinus | 1/0 | 19/w | 60 | 2 | 7 | 2,800 | 358.8 | 343.1 | 205 | 160 |
Crayfish | 2/0 | 7/w | 60 | 1 | 7 | 3,530 | 452.6 | 422.5 | 235 | 185 |
Sipho | 2/0 | 19/w | 60 | 1 | 7 | 3,530 | 441 | 422.5 | 235 | 185 |
Fulgar | 3/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 543.4 | 521.1 | 275 | 215 |
Arca | 4/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 671.2 | 644.6 | 315 | 245 |
AAC NEUTRAL-MESSENGER |
Haiotis | 6 | solid | 45 | 6 | 7 | 563 | 102.5 | 98.8 | 85 | 70 |
Patella | 6 | 7/w | 45 | 6 | 7 | 563 | 109.1 | 101.6 | 85 | 70 |
Fusus | 4 | solid | 45 | 4 | 7 | 881 | 151.9 | 147.6 | 115 | 90 |
Oyster | 4 | 7/w | 45 | 4 | 7 | 881 | 161.8 | 151.7 | 115 | 90 |
Clam | 2 | 7/w | 45 | 2 | 7 | 1,350 | 243.2 | 229.2 | 150 | 120 |
Murex | 1/0 | 7/w | 60 | 1/0 | 7 | 1,990 | 395.1 | 369.4 | 205 | 160 |
Purpura | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 386.1 | 369.4 | 205 | 160 |
Nassa | 2/0 | 7/w | 60 | 2/0 | 7 | 2,510 | 485.8 | 455.3 | 235 | 185 |
Melita | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 585.2 | 562.9 | 275 | 215 |
Portunus | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 723.9 | 697.3 | 315 | 245 |
Nannynose | 336.4 | 19/w | 80 | 336 | 19 | 6,146 | 1160 | 1118 | 420 | 325 |
WITH FULL SIZE ACSR MESSENGER |
Paludina | 6 | solid | 45 | 6 | '6/1 | 1,190 | 114 | 113 | 85 | 70 |
Voluta | 6 | 7/w | 45 | 6 | '6/1 | 1,190 | 120 | 113 | 85 | 70 |
Whelk | 4 | solid | 45 | 4 | '6/1 | 1,860 | 169 | 165 | 115 | 90 |
Periwinkle | 4 | 7/w | 45 | 4 | '6/1 | 1,860 | 176 | 172 | 115 | 90 |
Conch | 2 | 7/w | 45 | 2 | '6/1 | 2,850 | 267 | 261 | 150 | 120 |
Neritina | 1/0 | 7/w | 60 | 1/0 | '6/1 | 4,380 | 530 | 419 | 205 | 160 |
Cenia | 1/0 | 19/w | 60 | 1/0 | '6/1 | 4,380 | 426 | 416 | 205 | 160 |
Runcina | 2/0 | 7/w | 60 | 2/0 | '6/1 | 5,310 | 530 | 519 | 235 | 185 |
Triton | 2/0 | 19/w | 60 | 2/0 | '6/1 | 5,310 | 526 | 514 | 235 | 185 |
Cherrystone | 3/0 | 7/w | 60 | 3/0 | '6/1 | 6,620 | 656 | 643 | 250 | 200 |
Mursia | 3/0 | 19/w | 60 | 3/0 | '6/1 | 6,620 | 650 | 638 | 250 | 200 |
Razor | 4/0 | 7/w | 60 | 4/0 | '6/1 | 8,350 | 814 | 799 | 315 | 245 |
Zuzara | 4/0 | 19/w | 60 | 4/0 | '6/1 | 8,350 | 805 | 792 | 315 | 245 |
Limpet | 336.4 | 19/w | 80 | 336 | '6/1 | 8,680 | 1209 | 1167 | 420 | 325 |
WITH ACSR REDUCED SIZE MESSENGER |
Scallop | 4 | Solid | 45 | 6 | '6/1 | 1,190 | 148 | 144 | 115 | 90 |
Strombus | 4 | 7/w | 45 | 6 | '6/1 | 1,190 | 158 | 148 | 115 | 90 |
Cockle | 2 | 7/ w | 45 | 4 | '6/1 | 1,860 | 233 | 227 | 150 | 120 |
Janthina | 1/0 | 7/ w | 60 | 2 | '6/1 | 2,850 | 376 | 365 | 205 | 160 |
Ranella | 1/0 | 19/ w | 60 | 2 | '6/1 | 2,850 | 372 | 362 | 205 | 160 |
Quadruplex Service Drop-Aluminum Conductor
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Rating(Amps) |
Name | 1000 ft(lbs) |
| Size | Strand | Insulation | Size | Strand | Breaking | XLP | POLY | XLP | POLY |
| AWG | thickness | AWG | strength |
| | (mls) | | (lbs) |
AAC NEUTRAL-MESSNGER |
Clydesdale | 4 | Solid | 45 | 4 | 7 | 881 | 208 | 201.8 | 100 | 80 |
Pinto | 4 | 7/w | 45 | 4 | 7 | 881 | 223 | 207.9 | 100 | 80 |
Mustang | 2 | 7/w | 45 | 2 | 7 | 1,350 | 333 | 312.6 | 135 | 105 |
Criollo | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 529 | 504.5 | 180 | 140 |
Percheron | 2/0 | 19/w | 60 | 2/0 | 7 | 2,510 | 649 | 620.5 | 205 | 160 |
Hanoverian | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 799 | 765.6 | 235 | 185 |
Oldenburg | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 986 | 946.7 | 275 | 210 |
Lippizaner | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1,546 | 1,519.20 | 370 | 280 |
ACSR NEUTRAL-MESSNGER |
Morochuca | 6 | Solid | 45 | 6 | '6/1 | 1,190 | 152 | 147.4 | 75 | 60 |
Chola | 6 | 7/w | 45 | 6 | '6/1 | 1,190 | 162 | 151.7 | 75 | 60 |
Morgan | 4 | Solid | 45 | 4 | '6/1 | 1,860 | 226 | 220 | 100 | 80 |
Hackney | 4 | 7/w | 45 | 4 | '6/1 | 1,860 | 241 | 226.1 | 100 | 80 |
Palomino | 2 | 7/w | 45 | 2 | '6/1 | 2,850 | 362 | 342.6 | 135 | 105 |
Costena | 1/0 | 19/w | 60 | 1/0 | '6/1 | 4,380 | 575 | 550.6 | 180 | 140 |
Grullo | 2/0 | 19/w | 60 | 2/0 | '6/1 | 5,310 | 707 | 678.7 | 205 | 160 |
Suffolk | 3/0 | 19/w | 60 | 3/0 | '6/1 | 6,620 | 872 | 838.9 | 235 | 185 |
Appaloosa | 4/0 | 19/w | 60 | 4/0 | '6/1 | 8,350 | 1079 | 1039.2 | 275 | 210 |
Bronco | 336.4 | 19/w | 80 | 336.4 | '18/1 | 8,580 | 1613 | 1568.2 | 370 | 280 |
Gelding | 336.4 | 19/w | 80 | 4/0 | '6/1 | 8,350 | 1548 | 1494.3 | 370 | 280 |
|
6201 ALLOY NEUTRAL-MESSENGER |
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1019 | 979.7 | 275 | 210 |
Address:
Building 6, Qinhe Road, Zhongyuan District, Zhengzhou City, Henan Province, Zhengzhou, Henan, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Zhengzhou JINYUAN Wire and Cable Co., Ltd, as a professional cable manufacturer. We have get ISO9001 and CE certificates. Our Professional and complete cable solutions make JYTOP Cables become to the partner of choice for international companies around the world,
PRODUCTS & STANDARDS & International Market:
1). Bare Conductor:
All Aluminum Conductor (AAC),
All Aluminum Alloy Conductor (AAAC),
Aluminum Conductor Steel Reinforced (ACSR),
Aluminum Alloy Conductor Steel Reinforced (AACSR),
Aluminum Conductor Aluminum Coated Steel Reinforced (ACSR/AW),
Aluminum Conductor Aluminum Alloy Reinforced (ACAR),
Aluminum Conductor Steel Supported (ACSS),
Aluminum Conductor Aluminum Coated Steel Reinforced (ACSR/AW)
All Copper Conductors(ACC),
Aluminum Coated Steel Wire(ACS),
Copper Coated Steel Wire(CCS),
Copper Coated Aluminum(CCA),
Galvanized Steel Wire(GSW),
Enameled Wire - Enameled round Aluminum Wire & Enameled round copper Wire
2). Overhead Cable:
Aerial Bundled Cable (ABC).
XLPE Cable,
Flexible Cable,
Single Core Cable,
2 Core Cable,
3 Core Cable,
4 Core Cable.
3). Building wire and cable:
THHN /THWN Cable
TW/THW Cable
PVC Insulated Wire,
XLPE Insulated cable.
4. Power Cable:
Armored /Non-armored Power cable
AWA Cable
SWA Cable
Standards: IEC, ASTM, AS/NZ, SANS, BS, DIN, NF, JISC, etc.
We can meet customers′ special requirements, and provided OEM service.
Mainly Oversea Marketing: Southeast Asia, The Middle East, Africa, South America, so on.
We will be recognized as a professional Manufacturer in cable industry, through continuous improvement of our product quality, after sales service. We can give you the reliable solution for cable wires.
Company website: jytopcable.en.made-in-china.com