Basic Info.
Application
Construction, Underground, Industrial, Power Station
Voltage
Low and Medium Voltage Cable
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE
Standard Used
IEC 60502-2
Conductor Type
Circular Compacted or Sectoral Compacted
Transport Package
Packed in Wooden Drums
Product Description
240mm swa armoured cable structure
Firstly, before you but the 240mm swa armoured cable, you should know the structure of the cable. Usually, the 240mm xlpe cable due to medium voltage cable. Meanwhile, it has 240mm swa 33kv xlpe cable, 11kv, 0.6/1kv etc. And then, it including: 3C 240mm2 STA or SWA armoured cable.
At the same time, the conductor is: copper or aluminum or tinned copper. And the insulation is very important. Because of the 240mm 4 core armoured cable use age dependent of the insulation material quality. So, the xlpe insulation used in the cable production.
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on;Only the halogen free cables shall be generally produced complied with IEC61034 and 60754.
(1)0.6/ 1kV ,Three Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Three Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Three Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 10.7 | 13.5 | 15.2 | 130 | 253 | 355 | - | - | - |
2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.7 | 14.5 | 16.2 | 173 | 308 | 420 | - | - | - |
4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.9 | 15.7 | 17.4 | 227 | 374 | 500 | - | - | - |
6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 14.1 | 16.9 | 18.6 | 297 | 458 | 596 | - | - | - |
10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.7 | 18.4 | 21.1 | 413 | 591 | 886 | 236 | 414 | 709 |
16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.9 | 20.7 | 23.3 | 609 | 811 | 1142 | 314 | 517 | 847 |
25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.5 | 24.3 | 27.6 | 903 | 1145 | 1691 | 451 | 694 | 1240 |
35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 23.9 | 26.7 | 30.0 | 1187 | 1456 | 2068 | 550 | 814 | 1413 |
50 | 8.4 | 1.0 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 27.3 | 30.2 | 33.6 | 1563 | 1881 | 2571 | 712 | 1025 | 1701 |
70 | 10.0 | 1.1 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 1.9 | 26.4 | 29.4 | 33.9 | 2097 | 2403 | 3321 | 849 | 1133 | 1981 |
95 | 11.7 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 1.9 | 2.0 | 2.2 | 29.8 | 34.6 | 37.6 | 2834 | 3517 | 4238 | 1111 | 1751 | 2420 |
120 | 13.3 | 1.2 | 1.3 | 1.4 | 0.5 | 2.5 | 2.0 | 2.0 | 2.3 | 33.2 | 38.2 | 42.4 | 3560 | 4332 | 5510 | 1377 | 2105 | 3226 |
150 | 14.5 | 1.4 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.4 | 37.9 | 42.5 | 46.9 | 4406 | 5247 | 6577 | 1693 | 2492 | 3762 |
185 | 16.4 | 1.6 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.2 | 2.5 | 42.9 | 47.8 | 52.1 | 5491 | 6476 | 7960 | 2109 | 3050 | 4473 |
240 | 18.7 | 1.7 | 1.5 | 1.5 | 0.5 | 2.5 | 2.4 | 2.4 | 2.6 | 48.0 | 53.1 | 57.4 | 7144 | 8261 | 9914 | 2707 | 3779 | 5368 |
300 | 20.4 | 1.8 | 1.5 | 1.5 | 0.5 | 2.5 | 2.6 | 2.5 | 2.8 | 52.5 | 57.5 | 61.8 | 8903 | 10119 | 11914 | 3337 | 4508 | 6235 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(2)0.6/ 1kV ,3C+E Cores,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,3C+E Cores,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,3C+E Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
mm2 | mm | mm | mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.5 | 14.3 | 16.0 | 156 | 288 | 398 | - | - | - |
2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.7 | 15.4 | 17.2 | 211 | 355 | 478 | - | - | - |
4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 13.9 | 16.7 | 19.3 | 279 | 438 | 704 | - | - | - |
6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.4 | 18.1 | 20.8 | 370 | 544 | 831 | - | - | - |
10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.1 | 19.8 | 22.5 | 527 | 720 | 1036 | 286 | 479 | 795 |
16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 19.5 | 22.3 | 25.6 | 778 | 999 | 1509 | 386 | 607 | 1116 |
25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 22.6 | 25.4 | 28.7 | 1064 | 1318 | 1890 | 514 | 769 | 1340 |
35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.6 | 27.4 | 30.7 | 1340 | 1617 | 2241 | 610 | 883 | 1509 |
50 | 8.4 | 1.0 | 25 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 28.4 | 31.4 | 34.7 | 1808 | 2139 | 2870 | 807 | 1134 | 1851 |
70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 2.0 | 29.7 | 32.6 | 37.3 | 2446 | 2789 | 3831 | 988 | 1309 | 2280 |
95 | 11.7 | 1.1 | 50 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.1 | 33.7 | 38.1 | 41.1 | 3313 | 4049 | 4865 | 1307 | 2000 | 2764 |
120 | 13.3 | 1.2 | 70 | 1.3 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.3 | 36.3 | 40.9 | 43.9 | 4223 | 5033 | 5913 | 1631 | 2396 | 3223 |
150 | 14.5 | 1.4 | 70 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.1 | 2.4 | 41.3 | 46.0 | 50.2 | 5061 | 5993 | 7415 | 1940 | 2826 | 4190 |
185 | 16.4 | 1.6 | 95 | 1.4 | 1.4 | 0.5 | 2.5 | 2.4 | 2.2 | 2.5 | 46.6 | 51.4 | 55.6 | 6400 | 7446 | 9076 | 2453 | 3454 | 4983 |
240 | 18.7 | 1.7 | 120 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.4 | 2.7 | 52.4 | 57.3 | 61.8 | 8291 | 9484 | 11337 | 3137 | 4284 | 6032 |
300 | 20.4 | 1.8 | 150 | 1.5 | 1.5 | 0.5 | 2.5 | 2.7 | 2.6 | 2.8 | 58.0 | 63.0 | 67.1 | 10322 | 11659 | 13632 | 3864 | 5155 | 7058 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(3)0.6/ 1kV ,Four Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Four Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Four Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.5 | 14.3 | 16.0 | 156 | 288 | 398 | - | - | - |
2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.7 | 15.4 | 17.2 | 211 | 355 | 478 | - | - | - |
4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 13.9 | 16.7 | 19.3 | 279 | 438 | 704 | - | - | - |
6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.4 | 18.1 | 20.8 | 370 | 544 | 831 | - | - | - |
10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.1 | 19.8 | 22.5 | 527 | 720 | 1036 | 286 | 479 | 795 |
16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 19.5 | 22.3 | 25.6 | 778 | 999 | 1509 | 386 | 607 | 1116 |
25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 23.6 | 26.4 | 29.7 | 1161 | 1427 | 2025 | 559 | 825 | 1423 |
35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.8 | 26.3 | 29.1 | 32.6 | 1533 | 1828 | 2519 | 690 | 981 | 1658 |
50 | 8.4 | 1.0 | 1.2 | 1.0 | 0.2 | 2.0 | 1.7 | 1.6 | 1.9 | 30.1 | 33.0 | 37.3 | 2029 | 2379 | 3410 | 890 | 1235 | 2243 |
70 | 10.0 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 1.8 | 1.7 | 2.1 | 30.7 | 35.2 | 38.5 | 2764 | 3443 | 4222 | 1104 | 1739 | 2467 |
95 | 11.7 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 1.9 | 2.0 | 2.2 | 35.3 | 40.1 | 43.1 | 3746 | 4551 | 5417 | 1454 | 2212 | 3026 |
120 | 13.3 | 1.2 | 1.3 | 1.4 | 0.5 | 2.5 | 2.0 | 2.0 | 2.4 | 38.0 | 43.0 | 47.4 | 4697 | 5578 | 6942 | 1790 | 2624 | 3890 |
150 | 14.5 | 1.4 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.4 | 43.8 | 48.4 | 52.9 | 5816 | 6785 | 8368 | 2203 | 3126 | 4609 |
185 | 16.4 | 1.6 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.2 | 2.6 | 48.2 | 53.1 | 57.5 | 7239 | 8342 | 10050 | 2734 | 3791 | 5395 |
240 | 18.7 | 1.7 | 1.5 | 1.5 | 0.5 | 2.5 | 2.4 | 2.4 | 2.8 | 53.9 | 59.0 | 63.6 | 9424 | 10676 | 12612 | 3514 | 4718 | 6545 |
300 | 20.4 | 1.8 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.5 | 3.0 | 61.5 | 66.6 | 71.2 | 11782 | 13205 | 15361 | 4366 | 5742 | 7824 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(4)0.6/ 1kV ,4C+E Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,4C+E Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,4C+E Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.3 | 15.1 | 16.8 | 182 | 324 | 444 | - | - | - |
2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.7 | 16.4 | 18.2 | 249 | 404 | 537 | - | - | - |
4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.1 | 17.9 | 20.5 | 334 | 506 | 784 | - | - | - |
6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 16.7 | 19.5 | 22.1 | 446 | 635 | 944 | - | - | - |
10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 18.6 | 21.3 | 24.0 | 636 | 846 | 1192 | 335 | 545 | 891 |
16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.3 | 24.1 | 27.4 | 953 | 1194 | 1741 | 463 | 704 | 1251 |
25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.9 | 27.7 | 31.0 | 1337 | 1618 | 2255 | 621 | 901 | 1539 |
35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 27.4 | 30.4 | 33.7 | 1709 | 2028 | 2733 | 753 | 1068 | 1759 |
50 | 8.4 | 1.0 | 25 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 2.0 | 31.8 | 34.8 | 39.4 | 2313 | 2681 | 3808 | 1009 | 1372 | 2476 |
70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.1 | 33.2 | 37.6 | 40.7 | 3129 | 3857 | 4653 | 1340 | 2127 | 3000 |
95 | 11.7 | 1.1 | 50 | 1.3 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.3 | 37.6 | 42.2 | 45.2 | 4226 | 5064 | 5975 | 1755 | 2658 | 3616 |
120 | 13.3 | 1.2 | 70 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.1 | 2.4 | 42.3 | 47.0 | 51.1 | 5402 | 6356 | 7786 | 2244 | 3291 | 4882 |
150 | 14.5 | 1.4 | 70 | 1.4 | 1.4 | 0.5 | 2.5 | 2.4 | 2.2 | 2.5 | 45.7 | 50.4 | 54.7 | 6489 | 7515 | 9080 | 2641 | 3779 | 5532 |
185 | 16.4 | 1.6 | 95 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.4 | 2.7 | 50.6 | 55.5 | 59.9 | 8171 | 9323 | 11084 | 3329 | 4625 | 6592 |
240 | 18.7 | 1.7 | 120 | 1.6 | 1.5 | 0.5 | 2.5 | 2.7 | 2.6 | 2.9 | 57.0 | 62.2 | 66.3 | 10599 | 11940 | 13888 | 4233 | 5738 | 7873 |
300 | 20.4 | 1.8 | 150 | 1.7 | 1.5 | 0.5 | 3.15 | 2.9 | 2.8 | 3.1 | 63.3 | 68.9 | 74.0 | 13205 | 14742 | 17671 | 5200 | 6914 | 10136 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(5)0.6/ 1kV ,Five Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Five Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Five Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.3 | 15.1 | 16.8 | 182 | 324 | 444 | - | - | - |
2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.7 | 16.4 | 18.2 | 249 | 404 | 537 | - | - | - |
4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.1 | 17.9 | 20.5 | 334 | 506 | 784 | - | - | - |
6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 16.7 | 19.5 | 22.1 | 446 | 635 | 944 | - | - | - |
10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 18.6 | 21.3 | 24.0 | 636 | 846 | 1192 | 335 | 545 | 891 |
16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.3 | 24.1 | 27.4 | 953 | 1194 | 1741 | 463 | 704 | 1251 |
25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 25.8 | 28.6 | 31.9 | 1411 | 1701 | 2366 | 658 | 949 | 1614 |
35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 28.9 | 31.9 | 35.2 | 1889 | 2226 | 2954 | 832 | 1163 | 1878 |
50 | 8.4 | 1.0 | 1.2 | 1.2 | 0.2 | 2.0 | 1.9 | 1.8 | 2.0 | 33.4 | 36.4 | 40.9 | 2498 | 2883 | 4040 | 1110 | 1489 | 2623 |
70 | 10.0 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.2 | 36.6 | 41.1 | 44.3 | 3470 | 4271 | 5184 | 1471 | 2296 | 3211 |
95 | 11.7 | 1.1 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.3 | 41.3 | 45.9 | 50.1 | 4706 | 5621 | 7080 | 1940 | 2883 | 4353 |
120 | 13.3 | 1.2 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.2 | 2.4 | 45.9 | 50.8 | 54.9 | 5910 | 6962 | 8538 | 2426 | 3533 | 5179 |
150 | 14.5 | 1.4 | 1.5 | 1.4 | 0.5 | 2.5 | 2.4 | 2.3 | 2.6 | 51.5 | 56.4 | 60.5 | 7299 | 8476 | 10212 | 2948 | 4178 | 5981 |
185 | 16.4 | 1.6 | 1.5 | 1.5 | 0.5 | 2.5 | 2.6 | 2.5 | 2.8 | 56.5 | 61.6 | 65.9 | 9097 | 10407 | 12338 | 3685 | 5084 | 7136 |
240 | 18.7 | 1.7 | 1.6 | 1.5 | 0.5 | 2.5 | 2.8 | 2.7 | 3.0 | 63.8 | 69.2 | 73.2 | 11840 | 13363 | 15505 | 4704 | 6322 | 8574 |
300 | 20.4 | 1.8 | 1.7 | 1.7 | 0.5 | 3.15 | 3.0 | 2.9 | 3.2 | 70.7 | 76.3 | 81.7 | 14765 | 16474 | 19793 | 5783 | 7591 | 11067 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(6)0.6/ 1kV ,3C+2E Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,3C+2E Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,3C+2E Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.3 | 15.1 | 16.8 | 182 | 324 | 444 | - | - | - |
2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.7 | 16.4 | 18.2 | 249 | 404 | 537 | - | - | - |
4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.1 | 17.9 | 20.5 | 334 | 506 | 784 | - | - | - |
6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 16.7 | 19.5 | 22.1 | 446 | 635 | 944 | - | - | - |
10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 18.6 | 21.3 | 24.0 | 636 | 846 | 1192 | 335 | 545 | 891 |
16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.3 | 24.1 | 27.4 | 953 | 1194 | 1741 | 463 | 704 | 1251 |
25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.0 | 26.8 | 30.1 | 1234 | 1505 | 2116 | 578 | 849 | 1460 |
35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 25.9 | 28.7 | 32.0 | 1506 | 1797 | 2462 | 679 | 966 | 1617 |
50 | 8.4 | 1.0 | 25 | 1.2 | 1.0 | 0.2 | 1.6 | 1.8 | 1.7 | 1.9 | 30.4 | 33.3 | 36.6 | 2078 | 2429 | 3200 | 922 | 1269 | 2027 |
70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.5 | 2.0 | 1.9 | 1.8 | 2.0 | 32.3 | 36.7 | 39.7 | 2817 | 3527 | 4307 | 1201 | 1950 | 2773 |
95 | 11.7 | 1.1 | 50 | 1.2 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.2 | 36.6 | 41.0 | 44.0 | 3813 | 4611 | 5487 | 1593 | 2436 | 3348 |
120 | 13.3 | 1.2 | 70 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.4 | 41.9 | 46.5 | 50.9 | 4967 | 5894 | 7365 | 2044 | 3027 | 4569 |
150 | 14.5 | 1.4 | 70 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.1 | 2.4 | 44.7 | 49.5 | 53.7 | 5764 | 6773 | 8305 | 2343 | 3418 | 5052 |
185 | 16.4 | 1.6 | 95 | 1.5 | 1.4 | 0.5 | 2.5 | 2.4 | 2.3 | 2.6 | 50.0 | 54.9 | 59.0 | 7353 | 8496 | 10216 | 2975 | 4199 | 6006 |
240 | 18.7 | 1.7 | 120 | 1.5 | 1.5 | 0.5 | 2.5 | 2.6 | 2.5 | 2.8 | 56.2 | 61.3 | 65.6 | 9461 | 10763 | 12700 | 3778 | 5171 | 7227 |
300 | 20.4 | 1.8 | 150 | 1.6 | 1.5 | 0.5 | 2.5 | 2.8 | 2.6 | 3.0 | 62.7 | 67.9 | 72.0 | 11766 | 13238 | 15382 | 4632 | 6193 | 8413 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
Application:
Low Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Address:
Building 6, Qinhe Road, Zhongyuan District, Zhengzhou City, Henan Province, Zhengzhou, Henan, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Zhengzhou JINYUAN Wire and Cable Co., Ltd, as a professional cable manufacturer. We have get ISO9001 and CE certificates. Our Professional and complete cable solutions make JYTOP Cables become to the partner of choice for international companies around the world,
PRODUCTS & STANDARDS & International Market:
1). Bare Conductor:
All Aluminum Conductor (AAC),
All Aluminum Alloy Conductor (AAAC),
Aluminum Conductor Steel Reinforced (ACSR),
Aluminum Alloy Conductor Steel Reinforced (AACSR),
Aluminum Conductor Aluminum Coated Steel Reinforced (ACSR/AW),
Aluminum Conductor Aluminum Alloy Reinforced (ACAR),
Aluminum Conductor Steel Supported (ACSS),
Aluminum Conductor Aluminum Coated Steel Reinforced (ACSR/AW)
All Copper Conductors(ACC),
Aluminum Coated Steel Wire(ACS),
Copper Coated Steel Wire(CCS),
Copper Coated Aluminum(CCA),
Galvanized Steel Wire(GSW),
Enameled Wire - Enameled round Aluminum Wire & Enameled round copper Wire
2). Overhead Cable:
Aerial Bundled Cable (ABC).
XLPE Cable,
Flexible Cable,
Single Core Cable,
2 Core Cable,
3 Core Cable,
4 Core Cable.
3). Building wire and cable:
THHN /THWN Cable
TW/THW Cable
PVC Insulated Wire,
XLPE Insulated cable.
4. Power Cable:
Armored /Non-armored Power cable
AWA Cable
SWA Cable
Standards: IEC, ASTM, AS/NZ, SANS, BS, DIN, NF, JISC, etc.
We can meet customers′ special requirements, and provided OEM service.
Mainly Oversea Marketing: Southeast Asia, The Middle East, Africa, South America, so on.
We will be recognized as a professional Manufacturer in cable industry, through continuous improvement of our product quality, after sales service. We can give you the reliable solution for cable wires.
Company website: jytopcable.en.made-in-china.com