Gold Member Since 2013
Audited Supplier
Zhengzhou Jinyuan Wire and Cable Co., Ltd.

ABC Cable, Duplex Cable, Overhead Cable manufacturer / supplier in China, offering XLPE Insulated Aluminum Overhead Aerial Bundled Triplex ABC Cable, 11kv Aluminum Cable Steel Tape Armored Cable 3X150mm, 0.6/1kv ABC Cable, Aerial Bundle Cable, XLPE Insulated ABC Cable and so on.

(/ )

Supplier Homepage Product Overhead Insulated ABC Cable & URD cable XLPE Insulated Aluminum Overhead Aerial Bundled Triplex ABC Cable

XLPE Insulated Aluminum Overhead Aerial Bundled Triplex ABC Cable

FOB Price: US $2.87 / Meter
Min. Order: 2,000 Meters
Min. Order FOB Price
2,000 Meters US $2.87/ Meter
Get Latest Price
Production Capacity: 3000k/ Month
Transport Package: 100m/Rolls
Payment Terms: L/C, T/T, D/P

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: USE-RHH/RHW-2
  • Chow #2: 120 AMPS
  • Standard: ASTM, AS/NZS, BS, CSA, DIN, IEC...
  • Trademark: jytop
  • Origin: Zhengzhou, China
  • Shepherd #6: 70 AMPS
  • Terrier #4: 90 AMPS
  • Cores Number: Duplex ,Triplex, Quadruplex Kebel
  • Specification: based on ASTM or IEC or NF standards
  • HS Code: 8544492100
Product Description
low voltage ABC Cable with overhead power cable

Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger. Duplex Service Drop-Aluminum Conductor.

Standards: 
IEC60502, NF C33-209, GB 12527-90 
Rated voltage: 0.6/1kV 
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204. 

The basic construction is as follows: 
3 cores consisting of standard aluminium conductors, insulated with XLPE insulation 
+ One sheath lighting aluminium conductor with XLPE insulation(optional) 
+ One messenger Al-alloy conductor (bare or covered) 
The messenger conductor can be of galvanised steel wire also. 
The purpose of messenger wire is 
A) It acts as load bearing wire. 
B) It acts as earth or neutral conductor. 

To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75 degree for polyethylene insulated conductors or 90 degree for crossliked polyethylene(XLPE) insulated conductors. 
Aerial Bundle Cables
Voltage Designation : 0.6/1kV , 6.35/11kV or 19/33kV
Reference Standard TNB Specification, SESCO Specification guidelines
 
Code
Name
Phase ConductorBare Neutral MessengerWeight Per
1000 ft(lbs)
Rating(Amps)
Size
AWG
StrandInsulation
thickness
(mls)
Size
AWG
*StrandBreaking
strength
(lbs)
XLPPOLYXLPPOLY
AAC
Pekingese6solid4567/w56363.561.77070
Collie67/w4567/w56366.863.17070
Dachshund4solid4547/w88195.593.49090
Spaniel47/w4547/w881100.595.49090
Doberman27/w4527/w1,350152.7145.7120120
Malemute1/019/w601/07/w1,990242.6234.2160160
ACSR NEUTRAL-MESSENGER
Setter6solid4566/11.19075.073.27070
Shepherd67/w4566/11.19078.374.67070
Eskimo4solid4546/11.860113.7111.69090
Terrier47/w4546/11.860118.7113.69090
Chow27/w4526/12.850181.7174.7120120
Bull1/019/w601/06/14.380288.7280.3160160
6201 ALLOY NEUTRAL-MESSENGER
Chihuahua6solid4567/w1,11067.665.87070
Vizsla67/w4567/w1,11070.967.27070
Harrier4solid4547/w1,760102.099.99090
Whippet47/w4547/w1,760107.0101.99090
Schnauzer27/w4527/w2,800163.3156.2120120
Heeler1/019/w601/07/w4,460259.2250.8160160
Send your message to this supplier
Avatar
Miss Ailin
Marketing Development
*From:
To: Miss Ailin
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now