Gold Member Since 2013
Audited Supplier
Zhengzhou Jinyuan Wire and Cable Co., Ltd.

Nyy Cable, N2xy Cable, Nyy-J Cable manufacturer / supplier in China, offering Nayy Cable Nyy XLPE Insulated Sta Armored PVC Sheathed Power Cable N2xy, 11kv Aluminum Cable Steel Tape Armored Cable 3X150mm, 0.6/1kv ABC Cable, Aerial Bundle Cable, XLPE Insulated ABC Cable and so on.

(/ )

Supplier Homepage Product 0.6/1kV XLPE Insulated Power Cable Nayy Cable Nyy XLPE Insulated Sta Armored PVC Sheathed Power Cable N2xy

Nayy Cable Nyy XLPE Insulated Sta Armored PVC Sheathed Power Cable N2xy

FOB Price: US $5.5-96 / Meter
Min. Order: 1,000 Meters
Min. Order FOB Price
1,000 Meters US $5.5-96/ Meter
Get Latest Price
Production Capacity: 300km Per Month
Transport Package: Packed in Reels
Payment Terms: L/C, T/T, D/P

Request a custom order and have something just for you!

Send Customized Request
Product Catalog
Power cable
34 Products
Content
Product Image
Product Name
FOB Price
Port
Payment Terms
Product Package
Basic Info
  • Model NO.: 3*240mm2
  • Voltage: Low and Medium Voltage Cable
  • Insulation Material: XLPE
  • Material Shape: Round Wire
  • Certification: ISO
  • Brand: Jytop
  • Certificate: Ce, ISO 9001
  • Popular Size: Nyy-J Cable
  • Cores Number: 4 Cores
  • Specification: as per popular standards or clients′s requirement
  • HS Code: 8544601200
  • Application: Construction, Underground, Industrial, Power Station
  • Current: DC Cable
  • Sheath Material: PE or PVC
  • Wire Core Material: Copper
  • Model: Nyy,Nayy,N2xy,Nhxmh
  • Standard: ASTM, AS/NZS, BS, CSA, DIN, IEC...
  • Rated Voltage: 300/500V
  • Popular Sizes: Nayy
  • Trademark: JYTOP
  • Origin: Zhengzhou, China
Product Description
Nayy Cable Nyy  XLPE Insulated STA Armored PVC Sheathed Power cable N2XY cable

Voltage:  0.6/1KV,1.8/3KV, 3.6/6KV ,35kV and below.
Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.


Product Named:
1.     The meaning of cable model in letter and number:
T....................................Copper conductor
L....................................Aluminum conductor
YJ..................................XLPE
V....................................PVC
Y....................................PE
 
Armor code:
2....................................Double steel tape armor
3....................................Thin steel wire armor
4....................................Thick steel wire armor
6....................................(Double)non-magnetic mental tape armor
7....................................Non-magnetic wire armor
 
Oversheath code:
2....................................PVC oversheath
3....................................PE oversheath
4....................................Elastomer oversheath
 
Using Festures of Power Cable:
1.Rated Voltage 0.6/1kV PVC Insulation Power Cable :
The long-term working temperature of cable conductor should be not more than 70°C.
 While short-circuit the highest working temperature of cable conductor should be not more than 160°C(5 seconds maximum duration);
The minimum bending radius for laying cable(D is diameter):single core unarmoured cable shoule be 20D,multi-core unarmoured cable shoule be 15D,single core armoured cable shoule be 15D,multi-core armoured cable should be 12D;
The environment temperature for laying cable should be not less than 0°C.
 
2. Rated Voltage 0.6/1kV XLPE Insulation Power Cable / Rated Voltage 3.6/6~26/35kV XLPE Insulation Power Cable :
The long-term working temperature of cable conductor should be not more than 90°C.
While short-circuit the highest working temperature of cable conductor should be not more than 250°C(5 seconds maximum duration);
 
3. Rated Voltage 0.6/1kV and Freqency Inverter Control System Power Cable :
Designed with fully symmetric space structure,cable has excellent electromagnetic compatibility;
Low and uniform positive sequence and zero-sequence impedances have greatly improved power quality compared with ordinary four-core cable;
The environment temperature for laying cable;PVC and XLPE insulation is 0°C;
The maximum working temperature of cable;PVC insulation is 70°C,XLPE insulation is 90°C;
Low-smoke halogen-free flame retardant cable:PH value of burning gas ≥4.3,conductivity≤10us/mm,minimum light transmittance shall not be less than 60% while product burning;
The minimum bending radius for laying cable is 12D(D is diameter).
 
4. Copper Clad Aluminum Power Cable
Maximum temperature of cable of cable conductors during normal operation and short-circuit (5 seconds maximum duration): PVC insulation is 70oC, the highest temperature should be not more than 160oC while short circuit; XLPE insulation is 90oC,the highest temperature should be not more than 250oC while short circuit;
The minimum bending radius for laying cable (D is diameter):single core unarmoured is 20D,three-core unarmoured is 15D, single core armoured is 15D,three-core armoured is 12D; 
The environmental remperature for laying cable should not less than 0oC
 
 
Product description
Rated Voltage 0.6/1kV XLPE Insulation Power Cable
TypeDescriptionApplication
CuAl
YJVYJLVCopper-core(aluminum core)XLPE insulation and PVC sheath power cableFor laying indoor,in tunnels and in ducts,unable to bear external mechanical forces
YJYYJLYCopper-core(aluminum core)XLPE insulation and PE sheath power cable
YJV22YJLV22Copper-core(aluminum core)XLPE insulation steel tape armoured PVC sheath power cableFor laying indoor,in tunnels and in ducts,can able to bear external mechanical forces
YJV23YJLV23Copper-core(aluminum core)XLPE insulation steel tape armoured PE sheath power cable
YJV32YJLV32Copper-core(aluminum core)XLPE insulation steel wire armoured PVC sheath power cableFor laying in water or ground along route with large difference of level,can able to bear external mechanical forces
YJV33YJLV33Copper-core(aluminum core)XLPE insulation steel wire armoured PE sheath power cable
YJV42YJLV42Copper-core(aluminum core)XLPE insulation thick wire armoured PVC sheath power cable
YJV43YJLV43Copper-core(aluminum core)XLPE insulation thick wire armoured PE sheath power cable
Notes:1.Ratproof,termite-proof,moisture-proof and other special requiremments cables are available.
            2.The single core armoured cable are used for DC system only.As for AC system,non-megnetical materials shoule be used,its corresponding code is 62,63,72,73;
            3.It is not recommended AL-core fire retardent cable.When there is a fire,flame temperatures may reach 700°C above due to the meilting point of aluminium is only 660°C,the conductor may be fused;
           4.Flame retaradant/fire resistant power cable are available:Representation method of flame retardant grade is the "Z" followed by"A","B","C",such as the "ZA","ZB","ZC".When "ZR" expressed,generally considered to be "C" class of flame retardant.Flame retardant level representation is "ZN" middle "A","B","C",such as the "ZA","ZB","ZC".While using "NH" expressed,it generally considered to be "ZCN".For example;
 
Rated Voltage 0.6/1kV PVC Insulation Power Cable :
TypeDescriptionApplication
CuAl
VVVLVCopper-core(aluminum core)PVC insulation and PVC sheath power cableFor laying indoor,in tunnels and in ducts,unable to bear external mechanical forces
VYVLYCopper-core(aluminum core)PVC insulation and PE sheath power cable
VV22VLV22Copper-core(aluminum core)PVC insulation steel tape armoured PVC sheath power cableFor laying indoor,in tunnels and in ducts,can able to bear external mechanical forces
VY23VLY23Copper-core(aluminum core)PVC insulation steel tape armoured PE sheath power cable
VV32VLV32Copper-core(aluminum core)PVC insulation steel wire armoured PVC sheath power cableFor laying in water or ground along route with large difference of level,can able to bear external mechanical forces
VY33VLY33Copper-core(aluminum core)PVC insulation steel wire armoured PE sheath power cable
VV42VLV42Copper-core(aluminum core)PVC insulation thick wire armoured PVC sheath power cable
VY43VLY43Copper-core(aluminum core)PVC insulation thick wire armoured PE sheath power cable
Notes:1.Flexible power cable is available.Plus "R" after sheath material types.For example,"VVR" refers to cooper core PVC insulation PVC sheath flexible power cable;
            2.Hear-resistant 90°C and 105°C power cable are available,Plus "-90" "-105" after the type.For example,VV-105 refers to copper core heat-resistant 105°C PVC insulation and sheath power cable,and the highest temperature of cable conductor is 105°C.
            3.Ratproof,termite-proof,moisture-proof and other special requiremments cables are available.
            4.The single core armoured cable are used for DC system only.As for AC system,non-megnetical materials shoule be used,its corresponding code is 62,63,72,73;
            5.It is not recommended AL-core fire retardent cable.When there is a fire,flame temperatures may reach 700°C above due to the meilting point of aluminium is only 660°C,the conductor may be fused;
            6.Flame retaradant/fire resistant power cable are available:Representation method of flame retardant grade is the "Z" followed by"A","B","C",such as the "ZA","ZB","ZC".When "ZR" expressed,generally considered to be "C" class of flame retardant.Flame retardant level representation is "ZN" middle "A","B","C",such as the "ZA","ZB","ZC".While using "NH" expressed,it generally considered to be "ZCN".For example;
 
 
Size
Nominal thickness of XLPE insulation(mm)Approx. thickness of copper tape screen (mm)Nominal thickness of PVC or PE(mm)Approx. overall diameter of finished cable(mm)Max. conductor D.C resistance @ 20ºC(Ω/km)
1x50mm 210.50.122.138.20.387
1x70mm 210.50.122.240.10.268
1x95mm 210.50.122.241.70.193
1x120mm 210.50.122.343.30.153
1x150mm 210.50.122.344.90.124
1x185mm 210.50.122.446.70.0991
1x240mm 210.50.122.549.30.0754
1x300mm 210.50.122.551.30.0601
1x400mm 210.50.122.654.70.0470
1x500mm 210.50.122.758.20.0366
1x630mm 210.50.122.862.00.0283
1x800mm 210.50.123.066.20.0221
 
Size
Nominal thickness of XLPE insulation(mm)Approx. thickness of copper tape screen (mm)Nominal thickness of steel tape(mm)Nominal thickness of PVC or PE(mm)Approx. overall diameter of finished cable(mm)Max. conductor D.C resistance @ 20ºC(Ω/km)
3x25mm 23.40.100.52.345.70.727
3x35mm 23.40.100.52.448.10.524
3x50mm 23.40100.52.550.90.387
3x70mm 23.40.100.52.654.80.268
3x95mm 23.40.100.52.758.80.193
3x120mm 23.40.100.52.962.40.153
3x150mm 23.40.100.53.066.20.124
3x185mm 23.40.100.53.170.10.0991
3x240mm 23.40.100.53.375.90.0754
3x300mm 23.40.100.53.480.70.0601
3x400mm 23.40.100.83.789.80.0470
 
Cable size
 
Conductor type
Nominal thickness of XLPE insulation(mm)Nominal thickness of PVC or PE sheath(mm)Approx. cable overall diameter (mm)Max. D.C resistance @ 20ºC(Ω/km)
4x1.5mm 2RE or RM0.71.810.518.1
4x2.5mm 2RE or RM0.71.811.512.1
4x4mm 2RE or RM0.71.812.67.41
4x6mm 2RE or RM0.71.813.84.61
4x10mm 2RM0.71.816.93.08
4x16mm 2RM0.71.819.51.91
4x25mm 2SM0.91.821.31.20
4x35mm 2SM0.91.823.40.868
4x50mm 2SM1.01.926.80.641
4x70mm 2SM1.12.030.60.443
4x95mm 2SM1.12.134.90.320
4x120mm 2SM1.22.338.40.253
4x150mm 2SM1.42.442.50.206
4x185mm 2SM1.62.647.40.164
4x240mm 2SM1.72.853.40.125
4x300mm 2SM1.83.059.00.100
Send your message to this supplier
Avatar
Miss Ailin
Marketing Development
*From:
To: Miss Ailin
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category